CVE-2011-4875
Published Feb 3, 2012
Last updated 7 years ago
Overview
- Description
- Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
- Source
- cret@cert.org
- NVD status
- Modified
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 9.3
- Impact score
- 10
- Exploitability score
- 8.6
- Vector string
- AV:N/AC:M/Au:N/C:C/I:C/A:C
Weaknesses
- nvd@nist.gov
- CWE-119
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0" } ], "operator": "OR" } ] } ]