CVE-2011-4879
Published Feb 3, 2012
Last updated 7 years ago
Overview
- Description
- miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
- Source
- cret@cert.org
- NVD status
- Modified
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 8.5
- Impact score
- 7.8
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:N/A:C
Weaknesses
- nvd@nist.gov
- CWE-20
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1A4B1323-9AF3-424F-925A-A62F35E575E0" }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp2:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E454C72B-7804-402B-9C6A-687BF2C45D39" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc:*:sp2:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9FE44373-06BD-4AA0-8778-06F2A150510C", "versionEndIncluding": "v11" }, { "criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08" }, { "criteria": "cpe:2.3:a:siemens:wincc:v11:sp1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F53FDA20-FE97-4BA3-9165-F0BD7A25FA5F" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83" }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0" } ], "operator": "OR" } ] } ]