CVE-2012-5861
Published Nov 23, 2012
Last updated 7 years ago
Overview
- Description
- Multiple SQL injection vulnerabilities on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allow remote attackers to execute arbitrary SQL commands via (1) the inverterselect parameter in a primo action to dettagliinverter.php or (2) the lingua parameter to changelanguagesession.php.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Modified
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 7.5
- Impact score
- 6.4
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
- nvd@nist.gov
- CWE-89
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:sinapsitech:sinapsi_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "382C527D-16D4-4557-8E68-C4430416DB57", "versionEndIncluding": "2.0.2870" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:sinapsitech:esolar_duo_photovoltaic_system_monitor:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BF238DD2-D119-4652-B63B-9321DFB01A90" }, { "criteria": "cpe:2.3:h:sinapsitech:esolar_light_photovoltaic_system_monitor:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C00B699F-DE3B-4371-B814-DE54038C60A0" }, { "criteria": "cpe:2.3:h:sinapsitech:esolar_photovoltaic_system_monitor:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "288B1E9C-52C3-4ACC-807D-F650B850D874" } ], "operator": "OR" } ], "operator": "AND" } ]