- Description
- Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 6.1
- Impact score
- 6.9
- Exploitability score
- 6.5
- Vector string
- AV:A/AC:L/Au:N/C:N/I:N/A:C
Weaknesses
- nvd@nist.gov
- CWE-119
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6EFF12A0-B105-4225-B818-F858C75047B0", "versionEndIncluding": "8.0" }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636" }, { "criteria": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B34F3397-62D2-4D9C-A3DA-1BEE4A2A69FC", "versionEndIncluding": "7.1" }, { "criteria": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B4CB277F-7ECB-4F44-8BB5-A3D350486EE7" }, { "criteria": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "616535F1-F609-408B-AE48-61ACF48748A1" }, { "criteria": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7F322FCB-32F4-4C5A-A7F5-F7EF41188C88" }, { "criteria": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "69822DB4-DC79-4F88-A470-5AC512C77377" }, { "criteria": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "996DE8BD-DD51-41EF-9882-C2BD2CC5FE53" }, { "criteria": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "945C8B46-4CDA-4143-889C-30E30E93DB29" }, { "criteria": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A33F9015-7058-419A-8762-CB2AE4ACF1A7" }, { "criteria": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E6271FCC-CCF6-4D31-801A-B4B0DC4639DD" }, { "criteria": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DF7A6B2B-D573-4285-B3B4-136F2BE7E710" }, { "criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "111D0F4D-2B67-46E8-BF8D-5D30EFE561EE" } ], "operator": "OR" } ] } ]