- Description
- Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 7.8
- Impact score
- 6.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:N/I:N/A:C
Weaknesses
- nvd@nist.gov
- NVD-CWE-noinfo
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2A37383F-B3F7-423C-B956-87926E38B323", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C3D4A8F2-6ACC-4809-8320-7A0305741069", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7EBDF670-EA1F-45A4-8C2B-C52B5D2AF565", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0EC634AF-318C-4280-B0E3-1DE20C98962C", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D4A46E17-22DF-4FEB-B290-E209AF511B8E", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "233B1E82-769D-43AA-A051-CBAB0BD5F496", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1CBD5520-7F19-44DE-AA9B-1D00475B987F", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9E1B49EF-9276-47C7-ACE7-965B465BF202", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "919785E4-03B8-4BDF-9C3C-90538E24D13E", "versionEndExcluding": "4.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09" } ], "operator": "OR" } ], "operator": "AND" } ]