- A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.
- Source
- cve@mitre.org
- NVD status
- Modified
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 2.0
- Type
- Primary
- Base score
- 7.5
- Impact score
- 6.4
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
- nvd@nist.gov
- CWE-20
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "50D308F8-83C2-4404-9C12-7A033006A350", "versionEndIncluding": "5.0.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8B9CBC72-92D9-4B3A-884F-33124C457016" }, { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3268CF75-6DAB-416A-B19B-2A8F95C268CF" }, { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:-:pro:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "21095E8E-A67B-448C-90B1-6234D931C005" }, { "criteria": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A8B1D979-038F-42F4-AB7D-E0664D051B4E" }, { "criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CEB62730-E759-455A-A308-F9DB084B35B5" }, { "criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:-:pro:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "39CAF419-AB8D-4F79-A5E7-602A77D55E65" }, { "criteria": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15" }, { "criteria": "cpe:2.3:h:siemens:scalance_x204irt:-:-:pro:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BB688C82-7454-4FD0-B484-C400E7FF4898" }, { "criteria": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "57E5489B-277A-4D02-B4AB-4DB65969EED2" } ], "operator": "OR" } ], "operator": "AND" } ]