CVE-2017-11402

Published Nov 20, 2017

Last updated 5 years ago

Overview

Description
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift.
Source
cve@mitre.org
NVD status
Analyzed

Risk scores

CVSS 3.0

Type
Primary
Base score
9.8
Impact score
5.9
Exploitability score
3.9
Vector string
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity
CRITICAL

CVSS 2.0

Type
Primary
Base score
10
Impact score
10
Exploitability score
10
Vector string
AV:N/AC:L/Au:N/C:C/I:C/A:C

Weaknesses

nvd@nist.gov
CWE-20

Social media

Hype score
Not currently trending

Configurations