- Description
- An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
CVSS 2.0
- Type
- Primary
- Base score
- 5
- Impact score
- 2.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:N/A:N
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9CA3FF3A-9145-4DAD-BAD6-D55C97E182AA",
"versionEndIncluding": "4.0.3.20"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6FDB0710-FB7F-4346-9EEC-4C75ECEA0A1E",
"versionEndIncluding": "4.0.3.20"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
]