CVE-2018-10252

Published May 14, 2018

Last updated 3 days ago

Overview

Description
An issue was discovered on Actiontec WCB6200Q before 1.1.10.20a devices. The admin login session cookie is insecurely generated making admin session hijacking possible. When an admin logs in, a session cookie is generated using the time of day rounded to 10ms. Since the web server returns its current time of day in responses, it is possible to step backward through possible session values until a working one is found. Once a working session ID is found, an attacker then has admin control of the device and can add a secondary SSID to create a backdoor to the network.
Source
cve@mitre.org
NVD status
Modified

Risk scores

CVSS 3.0

Type
Primary
Base score
8.1
Impact score
5.9
Exploitability score
2.2
Vector string
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
6.8
Impact score
6.4
Exploitability score
8.6
Vector string
AV:N/AC:M/Au:N/C:P/I:P/A:P

Weaknesses

nvd@nist.gov
CWE-384

Social media

Hype score
Not currently trending

Configurations