Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
Source
productcert@siemens.com
NVD status
Modified

Risk scores

CVSS 3.0

Type
Primary
Base score
8.6
Impact score
6
Exploitability score
1.8
Vector string
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
4.4
Impact score
6.4
Exploitability score
3.4
Vector string
AV:L/AC:M/Au:N/C:P/I:P/A:P

Weaknesses

nvd@nist.gov
CWE-732
productcert@siemens.com
CWE-276

Social media

Hype score
Not currently trending

Configurations