- Description
- A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
- Source
- productcert@siemens.com
- NVD status
- Modified
CVSS 3.0
- Type
- Primary
- Base score
- 5.8
- Impact score
- 1.4
- Exploitability score
- 3.9
- Vector string
- CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N
- Severity
- MEDIUM
CVSS 2.0
- Type
- Primary
- Base score
- 5
- Impact score
- 2.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:N/A:N
- nvd@nist.gov
- NVD-CWE-noinfo
- productcert@siemens.com
- CWE-284
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:automation_license_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2FC27DF2-B9E3-4551-892B-1668B2CA63D7",
"versionEndExcluding": "5.3.4.4"
}
],
"operator": "OR"
}
]
}
]