Description
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.
Source
productcert@siemens.com
NVD status
Modified

Risk scores

CVSS 3.0

Type
Primary
Base score
8.6
Impact score
4
Exploitability score
3.9
Vector string
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
7.8
Impact score
6.9
Exploitability score
10
Vector string
AV:N/AC:L/Au:N/C:N/I:N/A:C

Weaknesses

nvd@nist.gov
CWE-20
productcert@siemens.com
CWE-20

Social media

Hype score
Not currently trending

Configurations