- Description
- An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
- Source
- cve@mitre.org
- NVD status
- Modified
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
CVSS 2.0
- Type
- Primary
- Base score
- 10
- Impact score
- 10
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:C/I:C/A:C
Data from CISA
- Vulnerability name
- Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability
- Exploit added on
- Nov 3, 2021
- Exploit action due
- May 3, 2022
- Required action
- Apply updates per vendor instructions.
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7",
"versionEndIncluding": "15.03.06.44_cn"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815",
"versionEndIncluding": "15.03.05.19\\(6318\\)_cn"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186",
"versionEndIncluding": "15.03.06.23_cn"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
]