CVE-2018-4842

Published Jun 14, 2018

Last updated 3 days ago

Overview

Description
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Source
productcert@siemens.com
NVD status
Modified

Risk scores

CVSS 3.0

Type
Primary
Base score
4.8
Impact score
2.7
Exploitability score
1.7
Vector string
CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Severity
MEDIUM

CVSS 2.0

Type
Primary
Base score
3.5
Impact score
2.9
Exploitability score
6.8
Vector string
AV:N/AC:M/Au:S/C:N/I:P/A:N

Weaknesses

productcert@siemens.com
CWE-79
nvd@nist.gov
CWE-79

Social media

Hype score
Not currently trending

Configurations