Overview
- Description
- For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user information such as authentication credentials.
- Source
- cybersecurity@ch.abb.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 6.5
- Impact score
- 3.6
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
- Severity
- MEDIUM
CVSS 2.0
- Type
- Primary
- Base score
- 4.3
- Impact score
- 2.9
- Exploitability score
- 8.6
- Vector string
- AV:N/AC:M/Au:N/C:P/I:N/A:N
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:esoms:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C5811C31-75D6-407F-9321-655972F35EAC", "versionEndIncluding": "6.0.2", "versionStartIncluding": "4.0" } ], "operator": "OR" } ] } ]