Overview
- Description
- A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
- Source
- productcert@siemens.com
- NVD status
- Modified
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 7.5
- Impact score
- 3.6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 5
- Impact score
- 2.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:N/I:N/A:P
Weaknesses
- productcert@siemens.com
- CWE-400
- nvd@nist.gov
- NVD-CWE-Other
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "96432C6B-6A9E-406F-9A64-9448CB786352" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB503096-C528-478C-BD07-019C2CC882E4" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "02DA7157-4088-4EB8-98AF-18C7D64F6AE4", "versionEndExcluding": "5.5.0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_pro_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A977EB4D-F64E-44CB-A3EF-CCE9F69D77BC" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-200irt_pro:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0CB57CFF-C367-4988-A3EE-889164B48034" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3F2C50BB-CC63-40BE-A5F0-0F0C342586CA" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B357AD42-1806-4BE5-B76D-F798E475F659" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "88638890-5ABE-4824-A41F-FCF30532A538" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F58423D0-954E-426E-9F8F-3DD95FBDF50C" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5B01B39C-0039-4126-95F2-6F691C5158A0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E478FE71-32D1-4FE4-8AC9-1C898EFFD0B3" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf180c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "167F39FD-FFB5-4C82-BE39-0787ED369546" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf180c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "62129B85-7C98-4951-8194-2E602A8DCDBD" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710" } ], "operator": "OR" } ], "operator": "AND" } ]