CVE-2019-19393

Published Oct 1, 2020

Last updated 4 years ago

Overview

Description
The Web application on Rittal CMC PU III 7030.000 V3.00 V3.11.00_2 to V3.15.70_4 devices fails to sanitize user input on the system configurations page. This allows an attacker to backdoor the device with HTML and browser-interpreted content (such as JavaScript or other client-side scripts) as the content is always displayed after and before login. Persistent XSS allows an attacker to modify displayed content or to change the victim's information. Successful exploitation requires access to the web management interface, either with valid credentials or a hijacked session.
Source
cve@mitre.org
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
6.1
Impact score
2.7
Exploitability score
2.8
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Severity
MEDIUM

CVSS 2.0

Type
Primary
Base score
4.3
Impact score
2.9
Exploitability score
8.6
Vector string
AV:N/AC:M/Au:N/C:N/I:P/A:N

Weaknesses

nvd@nist.gov
CWE-79

Social media

Hype score
Not currently trending

Configurations