CVE-2019-3704
Published Feb 7, 2019
Last updated 5 years ago
Overview
- Description
- VNX Control Station in Dell EMC VNX2 OE for File versions prior to 8.1.9.236 contains OS command injection vulnerability. Due to inadequate restriction configured in sudores, a local authenticated malicious user could potentially execute arbitrary OS commands as root by exploiting this vulnerability.
- Source
- security_alert@emc.com
- NVD status
- Modified
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.0
- Type
- Primary
- Base score
- 7.8
- Impact score
- 5.9
- Exploitability score
- 1.8
- Vector string
- CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 7.2
- Impact score
- 10
- Exploitability score
- 3.9
- Vector string
- AV:L/AC:L/Au:N/C:C/I:C/A:C
Weaknesses
- nvd@nist.gov
- CWE-78
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:emc_vnx2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2818A98E-B31B-4243-B85E-DD236199E4F6", "versionEndExcluding": "8.1.9.217" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:emc_vnx2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CF905D70-D7F1-460E-ADB4-5CBC545F0852" } ], "operator": "OR" } ], "operator": "AND" } ]