CVE-2019-6110
Published Jan 31, 2019
Last updated 2 years ago
Overview
- Description
- In OpenSSH 7.9, due to accepting and displaying arbitrary stderr output from the server, a malicious server (or Man-in-The-Middle attacker) can manipulate the client output, for example to use ANSI control codes to hide additional files being transferred.
- Source
- cve@mitre.org
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 6.8
- Impact score
- 5.2
- Exploitability score
- 1.6
- Vector string
- CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N
- Severity
- MEDIUM
CVSS 2.0
- Type
- Primary
- Base score
- 4
- Impact score
- 4.9
- Exploitability score
- 4.9
- Vector string
- AV:N/AC:H/Au:N/C:P/I:P/A:N
Weaknesses
- nvd@nist.gov
- CWE-838
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:openbsd:openssh:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "52D09A55-B853-43B5-8397-E2AC6CD0EBBC", "versionEndIncluding": "7.9" }, { "criteria": "cpe:2.3:a:winscp:winscp:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3D0A98E2-B715-4EF5-9CF8-07500E119271", "versionEndIncluding": "5.13" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:netapp:element_software:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "85DF4B3F-4BBC-42B7-B729-096934523D63" }, { "criteria": "cpe:2.3:a:netapp:ontap_select_deploy:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7E968916-8CE0-4165-851F-14E37ECEA948" }, { "criteria": "cpe:2.3:a:netapp:storage_automation_store:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7B7A6697-98CC-4E36-93DB-B7160F8399F9" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204rna_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0D3A0312-1249-4257-98F1-57E8959989C5", "versionEndExcluding": "3.2.7" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204rna:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "EA8B483F-0FD2-49F8-A86A-672A6E007949" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204rna_eec_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FC0C9671-47BB-43CB-8906-9BC2B86B3229", "versionEndExcluding": "3.2.7" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204rna_eec:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C834C295-D600-44E8-9783-49A319084F5A" } ], "operator": "OR" } ], "operator": "AND" } ]