CVE-2020-12005

Published Jun 15, 2020

Last updated 4 years ago

Overview

Description
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
Source
ics-cert@hq.dhs.gov
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
7.5
Impact score
3.6
Exploitability score
3.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
7.8
Impact score
6.9
Exploitability score
10
Vector string
AV:N/AC:L/Au:N/C:N/I:N/A:C

Weaknesses

nvd@nist.gov
CWE-434
ics-cert@hq.dhs.gov
CWE-434

Social media

Hype score
Not currently trending

Configurations