CVE-2020-12034
Published May 20, 2020
Last updated 4 years ago
Overview
- Description
- Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.2
- Impact score
- 4.7
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 4.8
- Impact score
- 4.9
- Exploitability score
- 6.5
- Vector string
- AV:A/AC:L/Au:N/C:N/I:P/A:P
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:eds_subsystem:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A38919F2-5EA3-4581-9034-C9D09A3CDEB3", "versionEndIncluding": "28.0.1" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:*", "vulnerable": true, "matchCriteriaId": "E52AA077-A130-4CBF-84C8-76E10D94C0E3", "versionEndIncluding": "4.11.00" }, { "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.00.00:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11B12B3C-8A2A-474E-8DE3-E666174800A0" }, { "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.10.00:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E0D6F9C0-CB2A-42FB-B3E2-4E43002C7579" }, { "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.11.00:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EEEB8D1D-C0C8-4CC6-A89D-98D788571217" }, { "criteria": "cpe:2.3:a:rockwellautomation:rsnetworx:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CBCDDC69-A4B2-4665-88C8-6B6A337C5CDC", "versionEndIncluding": "28.00.00" }, { "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7F9B29F9-ABAD-4E59-9298-528639F394F3", "versionEndIncluding": "32.0" } ], "operator": "OR" } ] } ]