CVE-2020-12523

Published Dec 17, 2020

Last updated 4 years ago

Overview

Description
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports get functional independent from their configuration setting: Missing Initialization of Resource
Source
info@cert.vde.com
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
9.1
Impact score
5.2
Exploitability score
3.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Severity
CRITICAL

CVSS 2.0

Type
Primary
Base score
6.4
Impact score
4.9
Exploitability score
10
Vector string
AV:N/AC:L/Au:N/C:P/I:N/A:P

Weaknesses

nvd@nist.gov
CWE-909
info@cert.vde.com
CWE-909

Social media

Hype score
Not currently trending

Configurations