- Description
- In SIMATIC MV400 family versions prior to v7.0.6, the ISN generator is initialized with a constant value and has constant increments. An attacker could predict and hijack TCP sessions.
- Source
- cve@mitre.org
- NVD status
- Modified
CVSS 3.1
- Type
- Primary
- Base score
- 7.5
- Impact score
- 3.6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 5
- Impact score
- 2.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:N/I:P/A:N
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "79B15C1B-2510-434B-A589-5903CA0C00EE"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AA65BD0C-3249-4AB6-A066-C55ADC06EDB7",
"versionEndExcluding": "7.0.6"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6408042E-7E06-4AED-9853-29B176EDFE9F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2FCC833E-AA77-471E-87CA-40B5E354163F",
"versionEndExcluding": "7.0.6"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
]