CVE-2020-3115
Published Jan 26, 2020
Last updated 5 years ago
Overview
- Description
- A vulnerability in the CLI of the Cisco SD-WAN Solution vManage software could allow an authenticated, local attacker to elevate privileges to root-level privileges on the underlying operating system. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending a crafted file to the affected system. An exploit could allow the attacker to elevate privileges to root-level privileges.
- Source
- ykramarz@cisco.com
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 6
- Exploitability score
- 2
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- Severity
- HIGH
CVSS 3.0
- Type
- Secondary
- Base score
- 8.8
- Impact score
- 6
- Exploitability score
- 2
- Vector string
- CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 7.2
- Impact score
- 10
- Exploitability score
- 3.9
- Vector string
- AV:L/AC:L/Au:N/C:C/I:C/A:C
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:cisco:sd-wan_firmware:18.4.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0015FD1E-1BCD-40AB-8C21-264AB9F6E123" }, { "criteria": "cpe:2.3:o:cisco:sd-wan_firmware:19.1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7797A89F-B23B-424B-B2F7-6165C5C616FD" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:cisco:vedge-100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5D71E4AF-6E91-4493-A591-4D056D0E59C1" }, { "criteria": "cpe:2.3:h:cisco:vedge-1000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F718A859-BCDB-4DD0-819D-60ABE710F0A9" }, { "criteria": "cpe:2.3:h:cisco:vedge-100b:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "07E7851F-3E72-4677-B907-CF777EBED2FF" }, { "criteria": "cpe:2.3:h:cisco:vedge-2000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "52EEF288-492C-4CE6-A082-631005C5E711" }, { "criteria": "cpe:2.3:h:cisco:vedge-5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C0C5E2C9-7D4B-405C-93DD-33DF265131E2" }, { "criteria": "cpe:2.3:h:cisco:vedge_100m:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "36973815-F46D-4ADA-B9DF-BCB70AC60BD3" }, { "criteria": "cpe:2.3:h:cisco:vedge_100wm:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "061A302C-8D35-4E80-93DA-916DA7E90C06" } ], "operator": "OR" } ], "operator": "AND" } ]