CVE-2020-7489
Published Apr 22, 2020
Last updated 3 years ago
Overview
- Description
- A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
CVSS 2.0
- Type
- Primary
- Base score
- 7.5
- Impact score
- 6.4
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:P/A:P
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_machine_expert:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E30E4E9A-2FD2-4F8E-B9EE-7771CEB93094" }, { "criteria": "cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2BCEA269-6242-41FD-B141-F72CAFC8F114" } ], "operator": "OR" } ] }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3FDBB3F0-20B6-4585-AEA1-F732C83AA791" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m100_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "817B5BC0-1368-4E03-994D-DECDC0B48F0F" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A184ABF9-9C27-46AB-88DB-78246FC779AF" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "802A6F54-4630-4434-A9DA-FCE7634F7C73" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "97963104-B620-4AE1-BD6C-7BF714497F78" } ], "operator": "OR" } ], "operator": "AND" } ]