Overview
- Description
- Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 7.1
- Impact score
- 5.2
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 3.6
- Impact score
- 4.9
- Exploitability score
- 3.9
- Vector string
- AV:L/AC:L/Au:N/C:P/I:P/A:N
Weaknesses
- cybersecurity@se.com
- CWE-522
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2", "versionEndExcluding": "15.0" }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3" }, { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911" }, { "criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "vulnerable": true, "matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7" } ], "operator": "OR" } ] } ]