CVE-2021-27475

Published Mar 23, 2022

Last updated 3 years ago

Overview

Description
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
Source
ics-cert@hq.dhs.gov
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
8.6
Impact score
6
Exploitability score
1.8
Vector string
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
6.8
Impact score
6.4
Exploitability score
8.6
Vector string
AV:N/AC:M/Au:N/C:P/I:P/A:P

Weaknesses

nvd@nist.gov
CWE-502
ics-cert@hq.dhs.gov
CWE-502

Social media

Hype score
Not currently trending

Configurations