CVE-2021-3118
Published Jan 11, 2021
Last updated 3 months ago
Overview
- Description
- EVOLUCARE ECSIMAGING (aka ECS Imaging) through 6.21.5 has multiple SQL Injection issues in the login form and the password-forgotten form (such as /req_password_user.php?email=). This allows an attacker to steal data in the database and obtain access to the application. (The database component runs as root.) NOTE: This vulnerability only affects products that are no longer supported by the maintainer
- Source
- cve@mitre.org
- NVD status
- Modified
- CNA Tags
- unsupported-when-assigned
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
CVSS 2.0
- Type
- Primary
- Base score
- 7.5
- Impact score
- 6.4
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
- nvd@nist.gov
- CWE-89
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:medicalexpo:ecs_imaging:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6A66AACD-2C42-4828-A1D9-FB43872A3CE1", "versionEndIncluding": "6.21.5" } ], "operator": "OR" } ] } ]