- Description
- A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
CVSS 2.0
- Type
- Primary
- Base score
- 10
- Impact score
- 10
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:C/I:C/A:C
- ics-cert@hq.dhs.gov
- CWE-89
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B201E2CD-43DB-4986-B032-5F411B4775BA",
"versionEndIncluding": "1.7.5"
}
],
"operator": "OR"
}
]
}
]