- Description
- A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 6.5
- Impact score
- 6.4
- Exploitability score
- 8
- Vector string
- AV:N/AC:L/Au:S/C:P/I:P/A:P
- productcert@siemens.com
- CWE-639
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "13870B36-3683-4B71-9322-CE26AB6724D3",
"versionEndExcluding": "12.4.0.8",
"versionStartIncluding": "12.4.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0AE45246-C5C8-42C4-807F-0C6D34C1200B",
"versionEndExcluding": "13.0.0.7",
"versionStartIncluding": "13.0.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A1360B8D-7874-413B-A6F0-6ACEA39236A2",
"versionEndExcluding": "13.1.0.5",
"versionStartIncluding": "13.1.0"
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4339F831-9FD8-4FD3-B874-F88F77B8081B",
"versionEndExcluding": "13.2.0.2",
"versionStartIncluding": "13.2.0"
}
],
"operator": "OR"
}
]
}
]