Overview
- Description
- The Device42 Remote Collector before 17.05.01 does not sanitize user input in its SNMP Connectivity utility. This allows an authenticated attacker (with access to the console application) to execute arbitrary OS commands and escalate privileges.
- Source
- cve@mitre.org
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 9
- Impact score
- 10
- Exploitability score
- 8
- Vector string
- AV:N/AC:L/Au:S/C:C/I:C/A:C
Weaknesses
- nvd@nist.gov
- CWE-78
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:device42:remote_collector:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "40756B62-51B7-4915-AF0A-25D26D780F2C", "versionEndExcluding": "17.05.01" } ], "operator": "OR" } ] } ]