CVE-2022-1118

Published May 17, 2022

Last updated 2 years ago

Overview

Description
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited
Source
ics-cert@hq.dhs.gov
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
7.8
Impact score
5.9
Exploitability score
1.8
Vector string
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Severity
HIGH

CVSS 2.0

Type
Primary
Base score
6.8
Impact score
6.4
Exploitability score
8.6
Vector string
AV:N/AC:M/Au:N/C:P/I:P/A:P

Weaknesses

ics-cert@hq.dhs.gov
CWE-502

Social media

Hype score
Not currently trending

Configurations