Overview
- Description
- The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- ics-cert@hq.dhs.gov
- CWE-306
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "01F624C6-079A-40BB-BA07-3441A6934850" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BE25BB24-A1BE-4904-935B-61E84CAAFD81", "versionEndIncluding": "1.0.3\\(3354\\)" } ], "operator": "OR" } ], "operator": "AND" } ]