- Description
- Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
- Source
- Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
- NVD status
- Modified
CVSS 3.1
- Type
- Primary
- Base score
- 5.5
- Impact score
- 3.6
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- Severity
- MEDIUM
CVSS 2.0
- Type
- Primary
- Base score
- 2.1
- Impact score
- 2.9
- Exploitability score
- 3.9
- Vector string
- AV:L/AC:L/Au:N/C:P/I:N/A:N
- nvd@nist.gov
- CWE-312
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "244286B8-A94E-451A-A79F-895B01BCE0FB",
"versionEndIncluding": "10.97",
"versionStartIncluding": "10.90"
},
{
"criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D31E1BFD-8194-4BA1-998B-BC4005454C15",
"versionEndExcluding": "10.95.210.01"
}
],
"operator": "OR"
}
]
}
]