CVE-2022-23449
Published Apr 12, 2022
Last updated 3 years ago
Overview
- Description
- A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 7.3
- Impact score
- 5.9
- Exploitability score
- 1.3
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 6.9
- Impact score
- 10
- Exploitability score
- 3.4
- Vector string
- AV:L/AC:M/Au:N/C:C/I:C/A:C
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178", "versionEndExcluding": "7.3" }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F" }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D", "versionEndExcluding": "7.3" }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525" } ], "operator": "OR" } ] } ]