- Description
- Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 7.5
- Impact score
- 3.6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Severity
- HIGH
Weaknesses
- ics-cert@hq.dhs.gov
- CWE-22
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0763E298-F79A-4604-B963-139473FC1368", "versionEndExcluding": "1.5.0.0" }, { "criteria": "cpe:2.3:a:deltaww:dialink:1.5.0.0:beta3:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8FC7C242-820D-4CF0-B408-78BC13C76BBE" } ], "operator": "OR" } ] } ]