Overview
- Description
- Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Modified
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.1
- Impact score
- 5.2
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Severity
- CRITICAL
Weaknesses
- ics-cert@hq.dhs.gov
- CWE-306
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0BC08CDF-4EE4-4E6D-AFF0-A4749A91A05D", "versionEndExcluding": "00.00.02a" } ], "operator": "OR" } ] } ]