CVE-2023-0808
Published Feb 13, 2023
Last updated 6 months ago
Overview
- Description
- A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
- Source
- cna@vuldb.com
- NVD status
- Modified
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 6.8
- Impact score
- 5.9
- Exploitability score
- 0.9
- Vector string
- CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- MEDIUM
CVSS 2.0
- Type
- Secondary
- Base score
- 3.7
- Impact score
- 6.4
- Exploitability score
- 1.9
- Vector string
- AV:L/AC:H/Au:N/C:P/I:P/A:P
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:deyeinverter:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AE9B754F-0502-43C0-A105-B586A59CFE07" }, { "criteria": "cpe:2.3:o:deyeinverter:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "62BC56BC-7AC1-4EEF-9C33-E3E5B004EDE6" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:deyeinverter:inverter:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CC029D39-994E-4A1C-8E20-B4B1E85472F4" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:revolt-power:inverter:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "975D2DD5-245A-4835-86BC-BED567097279" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:revolt-power:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "60232246-8FE3-4CE3-9208-7E3E568C779E" }, { "criteria": "cpe:2.3:o:revolt-power:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A9B91D9B-F89A-4F02-B12A-358A9D462174" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:bosswerk:inverter:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C1C1D833-293C-42B0-A3B9-479001F8E0F6" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:bosswerk:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C8E3410F-E68C-46E0-AF50-3A7E95962E70" }, { "criteria": "cpe:2.3:o:bosswerk:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FCBF9CAD-FA2D-413E-986C-AC988AEC758A" } ], "operator": "OR" } ], "operator": "AND" } ]