CVE-2023-1748
Published Apr 4, 2023
Last updated a year ago
Overview
- Description
- The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer.
- Source
- ics-cert@hq.dhs.gov
- NVD status
- Modified
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 10
- Impact score
- 6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- nvd@nist.gov
- CWE-798
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:getnexx:nxal-100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A105A0A9-453D-4FEC-A892-90DF700AF48F" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:getnexx:nxal-100_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "ECEB2E75-CBB4-4698-8362-E299B360D230", "versionEndIncluding": "nxal100v-p1-9-1" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:getnexx:nxg-100b:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "19767CB6-01EC-4D9A-B879-622D97659C41" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:getnexx:nxg-100b_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CFED44C1-D08F-485F-9613-2FF354646544", "versionEndIncluding": "nxg100bv-p3-4-1" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:getnexx:nxpg-100w:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BABBFCE0-C690-4867-9416-5C9E453A6B1F" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:getnexx:nxpg-100w_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "705949CF-FA4F-4D31-A125-897E4738FD60", "versionEndIncluding": "nxpg100cv4-0-0" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:getnexx:nxg-200:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E23E0481-74FD-4F0C-926C-D303DF9F9E68" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:getnexx:nxg-200_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5D3856AF-F315-4D54-A415-23D870E57FDC", "versionEndIncluding": "nxg200v-p3-4-1" } ], "operator": "OR" } ], "operator": "AND" } ]