CVE-2023-2071

Published Sep 12, 2023

Last updated 3 months ago

Overview

Description
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
Source
PSIRT@rockwellautomation.com
NVD status
Modified

Risk scores

CVSS 3.1

Type
Primary
Base score
9.8
Impact score
5.9
Exploitability score
3.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity
CRITICAL

Weaknesses

PSIRT@rockwellautomation.com
CWE-20
nvd@nist.gov
CWE-434

Social media

Hype score
Not currently trending

Configurations