CVE-2023-2186

Published Jun 7, 2023

Last updated a year ago

Overview

Description
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
Source
trellixpsirt@trellix.com
NVD status
Analyzed

Risk scores

CVSS 3.1

Type
Primary
Base score
9.8
Impact score
5.9
Exploitability score
3.9
Vector string
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Severity
CRITICAL

Weaknesses

nvd@nist.gov
CWE-134
trellixpsirt@trellix.com
CWE-134

Social media

Hype score
Not currently trending

Configurations