CVE-2023-24482
Published Feb 14, 2023
Last updated 2 years ago
Overview
- Description
- A vulnerability has been identified in COMOS V10.2 (All versions), COMOS V10.3.3.1 (All versions < V10.3.3.1.45), COMOS V10.3.3.2 (All versions < V10.3.3.2.33), COMOS V10.3.3.3 (All versions < V10.3.3.3.9), COMOS V10.3.3.4 (All versions < V10.3.3.4.6), COMOS V10.4.0.0 (All versions < V10.4.0.0.31), COMOS V10.4.1.0 (All versions < V10.4.1.0.32), COMOS V10.4.2.0 (All versions < V10.4.2.0.25). Cache validation service in COMOS is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- productcert@siemens.com
- CWE-120
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5EE12A9C-F1CC-4E67-A3FF-DBEEDBD4FF87", "versionEndExcluding": "10.3.3.1.45", "versionStartIncluding": "10.2" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0D6FCFC8-00D0-4A0E-B27A-F3A393A96838", "versionEndExcluding": "10.3.3.2.33", "versionStartIncluding": "10.3.3.2" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7751C0FE-268F-4DAD-9B10-25FC7E97A3BB", "versionEndExcluding": "10.3.3.3.9", "versionStartIncluding": "10.3.3.3" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7BD1A27A-5EE8-4AA1-B29D-0B534EC4E8B2", "versionEndExcluding": "10.3.3.4.6", "versionStartIncluding": "10.3.3.4" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1CA2B391-8BB4-4224-8BDE-B00817F82E3E", "versionEndExcluding": "10.4.0.0.31", "versionStartIncluding": "10.4.0.0" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "516D326A-E1CF-40ED-8B47-995CE0E51741", "versionEndExcluding": "10.4.1.0.32", "versionStartIncluding": "10.4.1.0" }, { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "895FAF07-0DA5-459E-8C72-F5566F9562B8", "versionEndExcluding": "10.4.2.0.25", "versionStartIncluding": "10.4.2.0" } ], "operator": "OR" } ] } ]