CVE-2023-26293

Published Apr 11, 2023

Last updated 3 months ago

Overview

Description
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
Source
productcert@siemens.com
NVD status
Modified

Risk scores

CVSS 3.1

Type
Primary
Base score
7.3
Impact score
5.5
Exploitability score
1.8
Vector string
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L
Severity
HIGH

Weaknesses

productcert@siemens.com
CWE-20
nvd@nist.gov
CWE-22

Social media

Hype score
Not currently trending

Configurations