Overview
- Description
- A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS.
- Source
- PSIRT@rockwellautomation.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 7.5
- Impact score
- 3.6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Severity
- HIGH
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_transaction_manager:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F257388C-3757-4714-9E3F-358FDC5C6C67", "versionEndIncluding": "13.10" } ], "operator": "OR" } ] } ]