- A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
Social media
- Hype score
- Not currently trending
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
Weaknesses
- cybersecurity@se.com
- CWE-306
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "93DB1B65-C1B5-4A20-ACA7-84EE9C07E9B1", "versionEndIncluding": "16.0.0.23040" }, { "criteria": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CCB39F06-042F-444C-819B-709FF63E060F", "versionEndIncluding": "16.0.0.23040" }, { "criteria": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AE9B5271-999B-4B2B-B4F3-8D99B3A78077", "versionEndIncluding": "16.0.0.23040" } ], "operator": "OR" } ] } ]