CVE-2023-29410
Published Apr 18, 2023
Last updated 2 years ago
Overview
- Description
- A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
Weaknesses
- cybersecurity@se.com
- CWE-20
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "371B602D-2BB3-41CF-B07B-558B74AEC130", "versionEndExcluding": "1.16" }, { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "698CF5CB-17DC-405B-9C44-675A80320A65" }, { "criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:build_004:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "039691CA-D243-4D6D-912A-F130F7F6491C" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:insighthome:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "37CAC057-7F0E-4375-99FE-AEE0EDDEA568" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "18E2843D-745F-41D7-8B16-2CC18EC64290", "versionEndExcluding": "1.16" }, { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F90B0024-6C86-4E85-AE83-F349D34E7416" }, { "criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:build_004:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D81ACD8E-4B04-4BCB-894F-4A5828899C16" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:insightfacility:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F5011815-3D43-4AA4-9395-31788D06DA10" } ], "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3524289C-ACF3-424E-9A1E-A777EBFB89F1", "versionEndExcluding": "1.16" }, { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "62314597-62BC-4531-B5C8-61343262CE9E" }, { "criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:build_004:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AD27299F-4422-4176-9DFD-86F2E4487366" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:conext_gateway:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E013171F-2BFB-4CB2-9C4B-4EB60A40B255" } ], "operator": "OR" } ], "operator": "AND" } ]