Overview
- Description
- Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
- Source
- cve@mitre.org
- NVD status
- Analyzed
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Weaknesses
- nvd@nist.gov
- CWE-306
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:kratosdefense:ngc_indoor_unit:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E4C89B61-E78C-4C19-908E-AE742DF997D0" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:kratosdefense:ngc_indoor_unit_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FB5EAD81-F368-4AB9-B87D-40C8830634D2", "versionEndExcluding": "11.4" } ], "operator": "OR" } ], "operator": "AND" } ]