CVE-2023-39460

Published May 3, 2024

Last updated 6 months ago

Overview

Description
Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.
Source
zdi-disclosures@trendmicro.com
NVD status
Awaiting Analysis

Risk scores

CVSS 3.0

Type
Secondary
Base score
7.2
Impact score
5.9
Exploitability score
1.2
Vector string
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Severity
HIGH

Weaknesses

zdi-disclosures@trendmicro.com
CWE-22

Social media

Hype score