CVE-2023-39464

Published May 3, 2024

Last updated 6 months ago

Overview

Description
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Source
zdi-disclosures@trendmicro.com
NVD status
Awaiting Analysis

Risk scores

CVSS 3.0

Type
Secondary
Base score
7.2
Impact score
5.9
Exploitability score
1.2
Vector string
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Severity
HIGH

Weaknesses

zdi-disclosures@trendmicro.com
CWE-428