Overview
- Description
- A vulnerability, which was classified as critical, has been found in D-Link DAR-8000-10 up to 20230819. Affected by this issue is some unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to os command injection. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-238574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
- Source
- cna@vuldb.com
- NVD status
- Modified
Risk scores
CVSS 3.1
- Type
- Primary
- Base score
- 8.1
- Impact score
- 5.9
- Exploitability score
- 2.2
- Vector string
- CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Secondary
- Base score
- 4.6
- Impact score
- 6.4
- Exploitability score
- 3.9
- Vector string
- AV:N/AC:H/Au:S/C:P/I:P/A:P
Weaknesses
- cna@vuldb.com
- CWE-78
Social media
- Hype score
- Not currently trending
Configurations
[ { "nodes": [ { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:dar-8000-10_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B402A316-BDF5-4E14-A81F-CEA0161B33FA", "versionEndIncluding": "20230819" } ], "operator": "OR" }, { "negate": false, "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:dar-8000-10:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D44DF047-CB1C-47CE-AC33-60F8859F242F" } ], "operator": "OR" } ], "operator": "AND" } ]